{"id":"c09b4e0c-138d-46a2-9b5d-70963b211a2a","created_at":"2026-06-16T20:07:38.036Z","updated_at":"2026-06-16T20:07:51.817Z","owner_id":"2bf8a7f2-1d3d-41b0-9e22-23105e9bed59","location_id":"922b03c0-fb16-4e23-9a95-83a09924a07e","dataset_id":"3dace7aa-130a-49cf-9966-e24114d160d4","form_id":"6a6c2644-5295-45b4-a8e3-f99063b91aee","observed_at":"2025-10-09T10:50:00.000Z","observed_at_local":"2025-10-09T11:50:00+01:00","notes":null,"checked":"review_needed","qa_notes":"Review needed: water_depth's result of 0.002m is below the normal range of 0.1m.","qa_admin_notes":"","qa_admin_notes_author_id":null,"qa_admin_notes_updated_at":null,"tested_parameters":["ammonia","flow","conductivity","water_temperature","turbidity","ph","water_depth","total_dissolved_solids_tds","phosphates"],"photos":[],"permalink":"https://data.waterrangers.com/observations/212398","readings":[{"id":"a5b0f00b-3a6e-4c57-85e7-b0204a4e2d17","created_at":"2026-06-16T20:07:38.061Z","updated_at":"2026-06-16T20:07:38.061Z","parameter":"ammonia","unit":"mg_l","value":"0.03","equipment":"hanna_checker_ammonia_medium_range","equipment_limit":null},{"id":"6fd9274c-edb9-481f-bded-d036bea4d34d","created_at":"2026-06-16T20:07:38.069Z","updated_at":"2026-06-16T20:07:38.069Z","parameter":"flow","unit":"l_s","value":"0.05","equipment":"other_flow_l_s","equipment_limit":null},{"id":"22024ef5-f9f8-4169-9fb7-051eb3c15a32","created_at":"2026-06-16T20:07:38.076Z","updated_at":"2026-06-16T20:07:38.076Z","parameter":"conductivity","unit":"us_cm","value":"1060","equipment":"other_pen_type_conductivity_meter_us_cm","equipment_limit":null},{"id":"6c416cb3-b595-4fc4-9ad1-de768a9509f7","created_at":"2026-06-16T20:07:38.085Z","updated_at":"2026-06-16T20:07:38.085Z","parameter":"water_temperature","unit":"deg_c","value":"11","equipment":"other_thermometer","equipment_limit":null},{"id":"ed072e5e-2bbc-4ad6-8bdf-67aab8e4adc8","created_at":"2026-06-16T20:07:38.091Z","updated_at":"2026-06-16T20:07:38.091Z","parameter":"turbidity","unit":"ntu","value":"14","equipment":"turbidity_tube_45cm","equipment_limit":"<="},{"id":"cd498445-6d80-4d8d-98b1-f37c14f71af1","created_at":"2026-06-16T20:07:38.099Z","updated_at":"2026-06-16T20:07:38.099Z","parameter":"ph","unit":"std_units","value":"6.97","equipment":"other_pen_type_ph_meter","equipment_limit":null},{"id":"cffc9d32-b669-4eb8-aeea-36af3d8e3f03","created_at":"2026-06-16T20:07:38.105Z","updated_at":"2026-06-16T20:07:38.105Z","parameter":"water_depth","unit":"m","value":"0.002","equipment":"ruler_m","equipment_limit":null},{"id":"231f69f6-171e-4786-8558-4eb54d183266","created_at":"2026-06-16T20:07:38.110Z","updated_at":"2026-06-16T20:07:38.110Z","parameter":"total_dissolved_solids_tds","unit":"ppm","value":"530","equipment":"other_pen-type_tds_meter","equipment_limit":null},{"id":"cf339b80-3dc0-487d-b062-871b42d83544","created_at":"2026-06-16T20:07:38.116Z","updated_at":"2026-06-16T20:07:38.116Z","parameter":"phosphates","unit":"mg_l","value":"0.07","equipment":"hanna_checker_phosphates_low_range","equipment_limit":null}]}