{"id":"cb561c59-d6c7-45f9-9c69-dec6507a9aac","created_at":"2025-08-28T17:32:54.936Z","updated_at":"2026-01-21T21:03:33.870Z","owner_id":"b03c60b5-011e-43b7-a004-0d527f78c5b6","location_id":"b5aa035a-403b-41fe-8072-58f485b7a763","dataset_id":"6631e734-6047-407b-9259-d0f7bece8180","form_id":"a7b94cbf-8f2f-4d5d-b4ca-7091db274ead","observed_at":"2018-02-21T16:35:00.000Z","observed_at_local":"2018-02-21T10:35:00-06:00","notes":"NOAA Dog River Water Levels station = 1.3 ft and rising. \r\nMost Probable Number of Enterococcus = 62 CFU/100mL","checked":"review_needed","qa_notes":"Review needed: Based on previous readings, conductivity's result of 10μS/cm is outside the expected range of 25.52-114.48μS/cm.","qa_admin_notes":"","qa_admin_notes_author_id":null,"qa_admin_notes_updated_at":null,"tested_parameters":["ph","oxygen","salinity","Fluorescence","conductivity","turbidity","air_temperature","water_temperature"],"photos":[],"permalink":"https://data.waterrangers.com/observations/105902","readings":[{"id":"2c42ca0e-0e1f-463e-ab3c-72a5ee91e18d","created_at":"2025-08-28T17:32:54.963Z","updated_at":"2025-08-28T17:32:54.963Z","parameter":"ph","unit":"std_units","value":"6.46","equipment":"lamotte_precision_ph","equipment_limit":null},{"id":"a7a0557f-d7b3-4da4-ac8a-d048d635aa7a","created_at":"2025-08-28T17:32:54.967Z","updated_at":"2025-08-28T17:32:54.967Z","parameter":"oxygen","unit":"mg_l","value":"6.8","equipment":"lamotte_dissolved_oxygen_mg_l","equipment_limit":null},{"id":"1433beb3-65c2-4d39-8c53-340a2e3d12fe","created_at":"2025-08-28T17:32:54.970Z","updated_at":"2025-08-28T17:32:54.970Z","parameter":"salinity","unit":"ppth","value":".03","equipment":"other_pen_type_salinity_meter_ppth","equipment_limit":null},{"id":"3e396ead-6ea7-47a6-846a-45879674979b","created_at":"2025-08-28T17:32:54.974Z","updated_at":"2025-08-28T17:32:54.974Z","parameter":"Fluorescence","unit":"ppm","value":"14.9","equipment":"fluorometer_ppm","equipment_limit":null},{"id":"9ef4b9af-8f2a-4578-8a90-e8427e98f9db","created_at":"2025-08-28T17:32:54.977Z","updated_at":"2025-08-28T17:32:54.977Z","parameter":"conductivity","unit":"us_cm","value":"10","equipment":"other_pen_type_conductivity_meter_us_cm","equipment_limit":null},{"id":"f7c24700-a751-4fd6-9f5e-7702b6ed7e93","created_at":"2025-08-28T17:32:54.980Z","updated_at":"2025-08-28T17:32:54.980Z","parameter":"turbidity","unit":"jtu","value":"7.67","equipment":"lamotte_turbidity","equipment_limit":null},{"id":"b30f03e7-4f7e-4fc4-9981-dbc6ce3fd4d2","created_at":"2025-08-28T17:32:54.984Z","updated_at":"2025-08-28T17:32:54.984Z","parameter":"air_temperature","unit":"deg_c","value":"24.4","equipment":"digital_thermometer_c","equipment_limit":null},{"id":"efc94b98-c2b6-4fd7-9b68-8bce919dba09","created_at":"2025-08-28T17:32:54.997Z","updated_at":"2025-08-28T17:32:54.997Z","parameter":"water_temperature","unit":"deg_c","value":"20.6","equipment":"other_multimeter_temperature","equipment_limit":null}]}