{"id":"03d87c9a-bc57-40e6-949b-e4f49f05bf4c","created_at":"2025-08-28T17:32:52.862Z","updated_at":"2026-01-02T18:30:33.288Z","owner_id":"b03c60b5-011e-43b7-a004-0d527f78c5b6","location_id":"49eefebe-1158-4d85-ab03-153c5fa1ecaa","dataset_id":"6631e734-6047-407b-9259-d0f7bece8180","form_id":"a7b94cbf-8f2f-4d5d-b4ca-7091db274ead","observed_at":"2018-02-08T17:40:00.000Z","observed_at_local":"2018-02-08T11:40:00-06:00","notes":"NOAA Dog River Water Levels station = -0.02 ft and rising. \r\n1st sample's Most Probable Number of Enterococcus = 62 CFU/100mL\r\n2nd sample's Most Probable Number of Enterococcus = 20 CFU/100mL\r\nWithin the 95% Confidence Interval\r\n","checked":"qc_complete","qa_notes":null,"qa_admin_notes":"","qa_admin_notes_author_id":null,"qa_admin_notes_updated_at":null,"tested_parameters":["ph","oxygen","salinity","Fluorescence","conductivity","air_temperature","water_temperature"],"photos":[],"permalink":"https://data.waterrangers.com/observations/105875","readings":[{"id":"df011a31-4885-4a0d-8618-86645260c901","created_at":"2025-08-28T17:32:52.894Z","updated_at":"2025-08-28T17:32:52.894Z","parameter":"ph","unit":"std_units","value":"7.36","equipment":"lamotte_precision_ph","equipment_limit":null},{"id":"5992c073-41f8-451c-a12e-49d2fa70fc2d","created_at":"2025-08-28T17:32:52.899Z","updated_at":"2025-08-28T17:32:52.899Z","parameter":"oxygen","unit":"mg_l","value":"9.2","equipment":"lamotte_dissolved_oxygen_mg_l","equipment_limit":null},{"id":"c447e008-2dff-47aa-a6b5-c48c84ec96bd","created_at":"2025-08-28T17:32:52.902Z","updated_at":"2025-08-28T17:32:52.902Z","parameter":"salinity","unit":"ppth","value":".07","equipment":"other_pen_type_salinity_meter_ppth","equipment_limit":null},{"id":"6c45ac48-3731-4457-bd64-415dc066db8f","created_at":"2025-08-28T17:32:52.906Z","updated_at":"2025-08-28T17:32:52.906Z","parameter":"Fluorescence","unit":"ppm","value":"55.2","equipment":"fluorometer_ppm","equipment_limit":null},{"id":"b520efc4-b77b-439b-a7c5-ebac049c2b7f","created_at":"2025-08-28T17:32:52.929Z","updated_at":"2025-08-28T17:32:52.929Z","parameter":"conductivity","unit":"us_cm","value":"150","equipment":"other_pen_type_conductivity_meter_us_cm","equipment_limit":null},{"id":"eb06f809-2ce8-4f43-9247-816e2ccee49c","created_at":"2025-08-28T17:32:52.934Z","updated_at":"2025-08-28T17:32:52.934Z","parameter":"air_temperature","unit":"deg_c","value":"18.6","equipment":"digital_thermometer_c","equipment_limit":null},{"id":"62b1b9c3-ec9e-44cd-8c21-502f41df11b5","created_at":"2025-08-28T17:32:52.945Z","updated_at":"2025-08-28T17:32:52.945Z","parameter":"water_temperature","unit":"deg_c","value":"16.1","equipment":"other_multimeter_temperature","equipment_limit":null}]}