{"id":"d5842df2-329b-4036-99a1-cb0d4a8f09e9","created_at":"2025-08-28T17:32:49.203Z","updated_at":"2026-01-02T18:30:19.955Z","owner_id":"b03c60b5-011e-43b7-a004-0d527f78c5b6","location_id":"0c222406-851e-40e6-b6a9-9a55cc72641b","dataset_id":"6631e734-6047-407b-9259-d0f7bece8180","form_id":"a7b94cbf-8f2f-4d5d-b4ca-7091db274ead","observed_at":"2018-01-23T14:33:00.000Z","observed_at_local":"2018-01-23T08:33:00-06:00","notes":"According to NOAA's Dog River Water Levels station, the tide was 0.32 ft and falling.\r\nMost Probable Number of Enterococcus = 126 CFU/100mL","checked":"review_needed","qa_notes":"Review needed: conductivity's result of 8660μS/cm exceeds the normal range of 5000.0μS/cm.","qa_admin_notes":"","qa_admin_notes_author_id":null,"qa_admin_notes_updated_at":null,"tested_parameters":["ph","oxygen","salinity","Fluorescence","conductivity","turbidity","air_temperature","water_temperature"],"photos":[],"permalink":"https://data.waterrangers.com/observations/105832","readings":[{"id":"d3505f7d-1032-49ce-83e3-c3dbd93f410d","created_at":"2025-08-28T17:32:49.230Z","updated_at":"2025-08-28T17:32:49.230Z","parameter":"ph","unit":"std_units","value":"6.46","equipment":"lamotte_precision_ph","equipment_limit":null},{"id":"5c157d0a-0724-4098-8438-7c99b4b6c8f7","created_at":"2025-08-28T17:32:49.235Z","updated_at":"2025-08-28T17:32:49.235Z","parameter":"oxygen","unit":"mg_l","value":"6.6","equipment":"lamotte_dissolved_oxygen_mg_l","equipment_limit":null},{"id":"3c25a820-3ba2-4c89-ac85-07d1d6f75b91","created_at":"2025-08-28T17:32:49.238Z","updated_at":"2025-08-28T17:32:49.238Z","parameter":"salinity","unit":"ppth","value":"5.06","equipment":"other_pen_type_salinity_meter_ppth","equipment_limit":null},{"id":"15f3d414-5084-4ec5-b2a4-97e8f1900117","created_at":"2025-08-28T17:32:49.241Z","updated_at":"2025-08-28T17:32:49.241Z","parameter":"Fluorescence","unit":"ppm","value":"21.5","equipment":"fluorometer_ppm","equipment_limit":null},{"id":"f47fb418-86d6-4bcb-8507-3a34e6b071f3","created_at":"2025-08-28T17:32:49.250Z","updated_at":"2025-08-28T17:32:49.250Z","parameter":"conductivity","unit":"us_cm","value":"8660","equipment":"other_pen_type_conductivity_meter_us_cm","equipment_limit":null},{"id":"a0f1e34a-dc0d-471f-948b-c4a6e3071a0c","created_at":"2025-08-28T17:32:49.253Z","updated_at":"2025-08-28T17:32:49.253Z","parameter":"turbidity","unit":"jtu","value":"3.43","equipment":"lamotte_turbidity","equipment_limit":null},{"id":"b8857d8a-c07e-412b-9c9b-f605508f4f96","created_at":"2025-08-28T17:32:49.257Z","updated_at":"2025-08-28T17:32:49.257Z","parameter":"air_temperature","unit":"deg_c","value":"12.1","equipment":"digital_thermometer_c","equipment_limit":null},{"id":"d4f83303-634e-4c52-bf21-92e07d9d21b2","created_at":"2025-08-28T17:32:49.260Z","updated_at":"2025-08-28T17:32:49.260Z","parameter":"water_temperature","unit":"deg_c","value":"12.2","equipment":"other_multimeter_temperature","equipment_limit":null}]}