{"id":"9ed1762a-4227-4a5a-8fc0-6911e3afa8f4","created_at":"2025-08-28T17:32:48.325Z","updated_at":"2026-01-02T18:30:16.803Z","owner_id":"b03c60b5-011e-43b7-a004-0d527f78c5b6","location_id":"fcde947c-3773-4fd9-a29a-1e8eff15901d","dataset_id":"6631e734-6047-407b-9259-d0f7bece8180","form_id":"a7b94cbf-8f2f-4d5d-b4ca-7091db274ead","observed_at":"2018-01-11T16:10:00.000Z","observed_at_local":"2018-01-11T10:10:00-06:00","notes":"According to NOAA's Dog River water levels station, the tide was 0.81 ft and rising.\r\nMost Probable Number of Enterococcus = 20 CFU/100mL","checked":"qc_complete","qa_notes":null,"qa_admin_notes":"","qa_admin_notes_author_id":null,"qa_admin_notes_updated_at":null,"tested_parameters":["ph","oxygen","salinity","Fluorescence","conductivity","turbidity","air_temperature","water_temperature"],"photos":[],"permalink":"https://data.waterrangers.com/observations/105825","readings":[{"id":"023d7020-a21c-4cf8-bef0-3ea7a7901054","created_at":"2025-08-28T17:32:48.362Z","updated_at":"2025-08-28T17:32:48.362Z","parameter":"ph","unit":"std_units","value":"8.13","equipment":"lamotte_precision_ph","equipment_limit":null},{"id":"3e2e55e8-625c-4201-9b90-466d6a386a85","created_at":"2025-08-28T17:32:48.366Z","updated_at":"2025-08-28T17:32:48.366Z","parameter":"oxygen","unit":"mg_l","value":"8.2","equipment":"lamotte_dissolved_oxygen_mg_l","equipment_limit":null},{"id":"93f1552e-7999-437e-9cd6-9e5d53da8483","created_at":"2025-08-28T17:32:48.376Z","updated_at":"2025-08-28T17:32:48.376Z","parameter":"salinity","unit":"ppth","value":".04","equipment":"other_pen_type_salinity_meter_ppth","equipment_limit":null},{"id":"c7a08b4a-15f2-4a87-9984-78f1e9cda7c2","created_at":"2025-08-28T17:32:48.385Z","updated_at":"2025-08-28T17:32:48.385Z","parameter":"Fluorescence","unit":"ppm","value":"15","equipment":"fluorometer_ppm","equipment_limit":null},{"id":"5ab9d688-67e5-4066-af22-967fb27e231e","created_at":"2025-08-28T17:32:48.390Z","updated_at":"2025-08-28T17:32:48.390Z","parameter":"conductivity","unit":"us_cm","value":"70","equipment":"other_pen_type_conductivity_meter_us_cm","equipment_limit":null},{"id":"a10fad93-5798-44e1-97ce-b413ec5b4e0d","created_at":"2025-08-28T17:32:48.394Z","updated_at":"2025-08-28T17:32:48.394Z","parameter":"turbidity","unit":"jtu","value":"4.43","equipment":"lamotte_turbidity","equipment_limit":null},{"id":"fcd57d8c-4b6a-403a-a5cd-a1fb1b540f16","created_at":"2025-08-28T17:32:48.400Z","updated_at":"2025-08-28T17:32:48.400Z","parameter":"air_temperature","unit":"deg_c","value":"21.2","equipment":"digital_thermometer_c","equipment_limit":null},{"id":"56f9fb93-6d39-4e0f-9cef-592d347b12b4","created_at":"2025-08-28T17:32:48.406Z","updated_at":"2025-08-28T17:32:48.406Z","parameter":"water_temperature","unit":"deg_c","value":"17.9","equipment":"other_multimeter_temperature","equipment_limit":null}]}