{"id":"e237ae75-d084-40c3-86ff-59e80978c3b4","created_at":"2025-08-28T17:32:43.107Z","updated_at":"2026-01-02T18:24:59.610Z","owner_id":"b03c60b5-011e-43b7-a004-0d527f78c5b6","location_id":"5a9c5609-673b-4506-8a5d-35ddcabc14dc","dataset_id":"6631e734-6047-407b-9259-d0f7bece8180","form_id":"a7b94cbf-8f2f-4d5d-b4ca-7091db274ead","observed_at":"2017-11-16T17:32:00.000Z","observed_at_local":"2017-11-16T11:32:00-06:00","notes":"Most Probable Number of Enterococcus = 82 CFU/100mL \r\nAccording to NOAA's Dog River Water Levels station, the tide was 1.68 and rising.","checked":"review_needed","qa_notes":"Review needed: conductivity's result of 12500μS/cm exceeds the normal range of 5000.0μS/cm.","qa_admin_notes":"","qa_admin_notes_author_id":null,"qa_admin_notes_updated_at":null,"tested_parameters":["ph","oxygen","salinity","Fluorescence","conductivity","turbidity","air_temperature","water_temperature"],"photos":[],"permalink":"https://data.waterrangers.com/observations/105756","readings":[{"id":"f349b951-3806-4808-bbd9-dbe16074c8f6","created_at":"2025-08-28T17:32:43.139Z","updated_at":"2025-08-28T17:32:43.139Z","parameter":"ph","unit":"std_units","value":"7.15","equipment":"lamotte_precision_ph","equipment_limit":null},{"id":"2071a118-18fb-4dca-b45c-3fce7b501d3b","created_at":"2025-08-28T17:32:43.142Z","updated_at":"2025-08-28T17:32:43.142Z","parameter":"oxygen","unit":"mg_l","value":"7.6","equipment":"lamotte_dissolved_oxygen_mg_l","equipment_limit":null},{"id":"07b0a58f-0c6b-4118-aa06-e13e85d3b23e","created_at":"2025-08-28T17:32:43.146Z","updated_at":"2025-08-28T17:32:43.146Z","parameter":"salinity","unit":"ppth","value":"6.5","equipment":"other_pen_type_salinity_meter_ppth","equipment_limit":null},{"id":"489e4228-eab9-4ad8-a1f1-c7e2d0942c42","created_at":"2025-08-28T17:32:43.149Z","updated_at":"2025-08-28T17:32:43.149Z","parameter":"Fluorescence","unit":"ppm","value":"33","equipment":"fluorometer_ppm","equipment_limit":null},{"id":"0d260eb4-a475-4b58-ae67-da96369a6c80","created_at":"2025-08-28T17:32:43.152Z","updated_at":"2025-08-28T17:32:43.152Z","parameter":"conductivity","unit":"us_cm","value":"12500","equipment":"other_pen_type_conductivity_meter_us_cm","equipment_limit":null},{"id":"e371832f-bb2f-41e3-a7c8-f266d71343e7","created_at":"2025-08-28T17:32:43.156Z","updated_at":"2025-08-28T17:32:43.156Z","parameter":"turbidity","unit":"jtu","value":"4.69","equipment":"lamotte_turbidity","equipment_limit":null},{"id":"4f6199ba-d382-4f6f-96d5-e1e3795afb27","created_at":"2025-08-28T17:32:43.159Z","updated_at":"2025-08-28T17:32:43.159Z","parameter":"air_temperature","unit":"deg_c","value":"19","equipment":"digital_thermometer_c","equipment_limit":null},{"id":"e6b2eb0d-cd51-42c9-bbd6-4cf7a02daf85","created_at":"2025-08-28T17:32:43.162Z","updated_at":"2025-08-28T17:32:43.162Z","parameter":"water_temperature","unit":"deg_c","value":"19.5","equipment":"other_multimeter_temperature","equipment_limit":null}]}