{"id":"61f6aea7-8dca-40de-a3ce-18cce1e3504f","created_at":"2025-08-28T17:32:42.842Z","updated_at":"2026-01-21T21:02:37.538Z","owner_id":"b03c60b5-011e-43b7-a004-0d527f78c5b6","location_id":"c7d0cec0-9436-4cc4-93e3-9d28963a1141","dataset_id":"6631e734-6047-407b-9259-d0f7bece8180","form_id":"a7b94cbf-8f2f-4d5d-b4ca-7091db274ead","observed_at":"2017-11-16T16:52:00.000Z","observed_at_local":"2017-11-16T10:52:00-06:00","notes":"Most Probable Number of Enterococcus = 20 CFU/100mL\r\nAccording to NOAA's Dog River Water Levels station, the tide was 1.59ft and rising.","checked":"review_needed","qa_notes":"Review needed: Based on previous readings, conductivity's result of 400μS/cm is outside the expected range of 47.76-92.24μS/cm.","qa_admin_notes":"","qa_admin_notes_author_id":null,"qa_admin_notes_updated_at":null,"tested_parameters":["ph","oxygen","salinity","Fluorescence","conductivity","turbidity","air_temperature","water_temperature"],"photos":[],"permalink":"https://data.waterrangers.com/observations/105752","readings":[{"id":"dfb9752f-8adb-49e2-b11f-3fdd8676e3fd","created_at":"2025-08-28T17:32:42.872Z","updated_at":"2025-08-28T17:32:42.872Z","parameter":"ph","unit":"std_units","value":"6.52","equipment":"lamotte_precision_ph","equipment_limit":null},{"id":"513190bd-fca2-4433-acaa-ff79371f5973","created_at":"2025-08-28T17:32:42.877Z","updated_at":"2025-08-28T17:32:42.877Z","parameter":"oxygen","unit":"mg_l","value":"8","equipment":"lamotte_dissolved_oxygen_mg_l","equipment_limit":null},{"id":"9dcb82a7-cd78-4a51-a7dd-41ac1dc6bb0e","created_at":"2025-08-28T17:32:42.881Z","updated_at":"2025-08-28T17:32:42.881Z","parameter":"salinity","unit":"ppth","value":".21","equipment":"other_pen_type_salinity_meter_ppth","equipment_limit":null},{"id":"eafee998-ec99-47d4-a312-ae3103167155","created_at":"2025-08-28T17:32:42.885Z","updated_at":"2025-08-28T17:32:42.885Z","parameter":"Fluorescence","unit":"ppm","value":"10.7","equipment":"fluorometer_ppm","equipment_limit":null},{"id":"60d930b4-1dd7-48b5-b4f5-df17e6e0823e","created_at":"2025-08-28T17:32:42.893Z","updated_at":"2025-08-28T17:32:42.893Z","parameter":"conductivity","unit":"us_cm","value":"400","equipment":"other_pen_type_conductivity_meter_us_cm","equipment_limit":null},{"id":"e43a5f85-aab7-475c-9650-c89f6cf8dc77","created_at":"2025-08-28T17:32:42.897Z","updated_at":"2025-08-28T17:32:42.897Z","parameter":"turbidity","unit":"jtu","value":"4.69","equipment":"lamotte_turbidity","equipment_limit":null},{"id":"a4e38793-f79c-4fa1-be15-1588df4d1b18","created_at":"2025-08-28T17:32:42.900Z","updated_at":"2025-08-28T17:32:42.900Z","parameter":"air_temperature","unit":"deg_c","value":"20","equipment":"digital_thermometer_c","equipment_limit":null},{"id":"e68bc2af-4c17-43fe-8b50-734df255322d","created_at":"2025-08-28T17:32:42.903Z","updated_at":"2025-08-28T17:32:42.903Z","parameter":"water_temperature","unit":"deg_c","value":"17.3","equipment":"other_multimeter_temperature","equipment_limit":null}]}